100 Amp 4 Pole Changeover Switch Price

100 Amp 4 Pole Changeover Switch Price

Automatic Transfer Switch, 4 Pole, 100/160/250 Amps

v out of v based on three reviews | Write a review

$358.54

$450.95

Auto transfer switch (ATS) is available with rated current 100 amp, 160 amp and 250 amp, 4-Pole transfer switch, used in the distribution system with rated voltage 400V Air-conditioning 50Hz, with functions of full auto, forcedly switching off "0" position, remote control and manual emergency performance etc. Fast switch on and off the circuit or transfer between dual power sources, to achieve the prophylactic isolation.

*
*

Free Aircraft Worldwide

Delivery date: 6-12 days

Features

  • Suitable for operating in the distribution system of rated voltage 400V AC 50Hz, and conventional thermal current upwards to 250 Amperes.
  • With the office of voltage detection, forcedly switching off "0" position, manual emergency operation, etc.
  • ATS is widely used to transfer between normal power and standby ability or two loading equipment, or performs prophylactic isolation and so on.
  • Automatic transfer switch is integrated with switching function and logic control, truly achieving electromechanical integration function.

Specification

Model ATO-ZMQ5
Rated Operating Voltage Ue 400V Air-conditioning
Rated Operating Frequency 50Hz
Rated Insulation Voltage Ue 690V Air conditioning
Coventional Thermal Current (Amp) 100A 160A 250A
Rated Insulation Voltage Ui 750V
Rated Impulse Withstand Current Uimp 8kV
Rated Operating Electric current Ie (Amp) Air conditioning-31A 100A 160A 250A
Ac-35A 100A 160A 250A
Air conditioning-33A 100A 160A 250A
Rated Short Time Withstand Current Icw 7kV 9kV
Rated Brusque-circuit Electric current Limit 100kA
Control Supply Voltage 220V Air conditioning
Transfer Time 0.5s 1s 1.1s
Number of Poles 4-Pole
ATS Controller Mode (Optional) * Type Ⅰ Total machine
Blazon Ⅱ Full car + forcedly switching off "0" position
Type Ⅲ Full auto + remote command
Standards Compliance to IEC6094-6-1, GB14048.eleven-2008
Weight 18kg 30kg 39kg
Dimensions See below

* For the specific functions of ATS controller mode, please check beneath:

  • Full machine
    When normal power is off, the ATS will automatically transfer to standby ability; when normal ability recovers, ATS will auto-transfer dorsum to normal power.
  • Forcedly switching off "0" position
    Push "0" button forcedly, and ATS volition cut off two loops of power supply.
  • Remote command
    Push "I" button, and normal power will be in service; push "II" push button, and backup power will be put into employ; button "0" push, and two loops of power supply volition be cut off.

Dimensions (Unit: mm)

100A/160A/250A Auto Transfer Switch Dimensions

Type A A1 B B1 C E G J M L N P R S T U Westward Ten Y Y1
100A/4P 247 244 106 105 134 143 115 233.5 84 7 74.5 30 fourteen 18 two.v 105 126 Φ6 36 86
160A/4P 322 300 135 128 230 189 145 284 102 7 91 36 20 25 3.5 127 158 Φ9 55 125
250A/4P 406 362 170 142 261 208 145 343 102 seven 91 50 25 30 3.5 142 168 Φ11 threescore 145

Wiring Diagram & Mounting Method

1. Wiring diagram

Auto Transfer Switch Wiring Diagram

2. Mounting method

Auto Transfer Switch Mounting Methods

ATS Structure

one. Electric primal
Switch on/off the power source of command circuit in the ATS. When the electric lock is switched on, ATS can execute the full auto operation, remote control, and forcedly switching off "0" performance; when electric lock is off, ATS tin only be operated manually.

two. Operating handle
Before using the operating handle, please be certain to turn off the electric lock.

three. Padlock
Special for inspection and repair, namely, offset make the ATS in "0" position by the operating handle, pull the padlock to lock for security reasons, and so conduct out the inspection and repair. (When the padlock is locked, information technology cuts off power source of inner control circuit, thus ATS cannot exist operated neither automatically or manually.)

4. Indication function
Point the working positions: I, 0, Two.

250A Auto Transfer Switch Structure

Tips: Transfer time of automatic transfer switch

When the ATS switches to the standby power supply, in that location is a filibuster, which is mainly used in the conversion from the main power supply to the standby power supply. However, some electrical equipment has strict requirements on the conversion fourth dimension of the double-power automatic transfer switch, so the transfer time of the dual-power automated switch option must be considered. The following are some requirements of switching fourth dimension for some electrical equipment for automatic transfer switch.

1. If the dual-power automatic transfer switch has the function of self-switching and cocky-replicating, when the primary ability supply resumes, the automatic transfer switch shall switch back to the primary power supply later delay.

two. Double-ability automatic transfer switch mostly is not immune to changeover big motor or high inductive load. Such load switching in operation, when the stage difference between the two power supplies is large, the motor will exist discipline to huge mechanical stress. At the same time, the overcurrent caused by the dorsum potential generated past the motor will cause fuse blown or circuit breaker trip. Therefore, when the automatic transfer switch used for large motor or high inductive load conversion, the two groups of moving contacts should add together a filibuster time before conversion, that is, the delay conversion type dual power automatic switch should exist selected, and the delay fourth dimension shall be determined according to the load situation.

iii. When the generator set up is used every bit the emergency lighting power supply, the total fourth dimension for starting the generator and power conversion shall not be greater than 15s.

four. When the low-voltage distribution system in the substation is operated in sections by a single bus and busbar switch is fix, the full action fourth dimension of the automatic transfer switch should be coordinated with the setting value of the activeness time set up by the busbar switch in the substation, which should be more than 0.v-1 second. The action time of busbar switch in the substation is mostly 2.5s, and the total activity time of automated transfer switch should be more than 3s.

This video will give yous an overview of ATO Automatic Transfer Switch, iv Pole, 100/160/250 Amps.

Existing reviews of Automatic Transfer Switch, four Pole, 100/160/250 Amps

Proficient transfer switch, easy to install and utilize.

Excellent production. Like shooting fish in a barrel to install and easy to apply. I have already made several times examination and it worked every bit advertised. Very uncomplicated to transfer from the master to generator power and dorsum.

From: David | Date: 15/11/2018

Was this review helpful? Yep No (0/0)

Very solid transfer switch.

Very solid transfer switch. I've connected information technology to the mains every bit common power and my generator as backup ability. No trouble with the wiring. Both the transmission and automatic changeover work as expected.

From: Kiel | Appointment: 17/03/2020

Was this review helpful? Yes No (0/0)

Connection of your 160 amps automatic transfer switch

I have a question about the connection of your this type of 160 amps ATS, in electrical control connexion does it require additional connection for being automatic?

From: Charles | Date: 13/04/2020

Was this review helpful? Yes No (0/0)

No additional connections are required for beingness automatic. Only select Type 1 for ATS controller model, which ways total auto, Then:-
When normal power is off, the ATS volition automatically transfer to standby power.
when normal power recovers, ATS volition car-transfer back to normal power.